Mfg Part Number: 0022935741 | Manufacturer: Syntegra Usa Inc | NSN : 5925-01-342-5703 |
Item Name : Circuit Breaker | CAGE Code : 59661 | FSC : 5925 Circuit Breakers |
Thank you for your vested interest in procuring the Circuit Breaker part types you require from The Distribution Pro! We currently have the Syntegra Usa Inc item you require available and listed alongside the part number 0022935741 and the NSN 5925-01-342-5703. To begin the procurement process for part 0022935741 or any item, submit a Request for Quote (RFQ) form with all details relevant to your purchase. Our team of market experts use data such as target prices, shipping deadlines, and desired quantities to formulate customized quotations for your comparisons, all within 15 minutes or less.
With cost savings and rapid lead times, our inventory of manufacturer Syntegra Usa Inc items like NSN 5925-01-342-5703 is organized to promote a procurement process that follows the motto: “as soon as possible, as simple as possible.” You can find Part 0022935741 listed next to the CAGE Code 59661 under FSC 5925 Circuit Breakers or you can search for specific details to find any other product you have in mind. As quality is the cornerstone of our operations, all NSN parts are sourced reliably from trusted manufacturers and shipped to you alongside all applicable trace documentation. Furthermore, we are an AS9120B, ISO 9001:2015, and FAA AC 00-56B accredited enterprise with a strict No China Sourcing policy, ensuring the premium quality of our inventory. When you are ready to begin procuring any item, submit an RFQ or contact us via phone or email for one-on-one assistance.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-342-5703 Item Description: Circuit Breaker | 5925 | 013425703 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
0022935741 | 5 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
CPRQ | RESET METHOD | MANUAL |
CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 1 TOGGLE |
CPRW | ACTUATOR FUNCTION | TRIP-RESET |
CPRX | ACTUATOR POSITION DESIGNATION | AT POLE TWO |
CPSF | ADJUSTABLE TRIP SETTING CURRENT RANGE PER POLE IN AMPS | +1250.0/+2500.0 AC ALL LOCATIONS |
TTQY | TERMINAL TYPE AND QUANTITY | 6 COMPRESSION |
AAQL | BODY STYLE | MULTIPOLE-SINGLE ACTUATOR TYPE |
ADAQ | BODY LENGTH | 14.750 INCHES NOMINAL |
ADAT | BODY WIDTH | 6.000 INCHES NOMINAL |
AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 9.250 INCHES NOMINAL |
AEBQ | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | 2.000 INCHES NOMINAL |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.196 INCHES NOMINAL |
AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 9.250 INCHES NOMINAL |
AJEC | BOSS HEIGHT | 1.970 INCHES NOMINAL |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 UNTHREADED HOLE |
BBRJ | SPECIAL HANDLING FEATURE | MAGNETIC |
CBBL | FEATURES PROVIDED | ADJUSTABLE TRIP RELEASE |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 250.0 AMPERES AC ALL LOCATIONS AND 250.0 AMPERES DC ALL LOCATIONS |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 600.0 AC ALL LOCATIONS AND 250.0 DC ALL LOCATIONS |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 18000.0 AC ALL LOCATIONS |
CPRL | TRIP RELEASE CHARACTERISTIC | INSTANTANEOUS ALL LOCATIONS |
CRCF | TRIP RELEASE AMBIENT TEMP RATING | 40.0 DEG CELSIUS NOMINAL ALL LOCATIONS |
AEHA | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 1.000 INCHES NOMINAL |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 125.0 ALL LOCATIONS |
ADTV | CASE MATERIAL | PLASTIC |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | DUSTPROOF |
FREQ | FREQUENCY IN HERTZ | 60.0 ALL LOCATIONS |
ADAU | BODY HEIGHT | 4.370 INCHES NOMINAL |
AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
AKPX | POLE QUANTITY | 3 |
APNQ | ARC QUENCHING METHOD | MAGNETIC BLOWOUT |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS |
CPRJ | TRIP RELEASE METHOD | THERMAL-MAGNETIC ALL LOCATIONS |