Mfg Part Number: 4512 | Manufacturer: Precision Electronics Corp | NSN : 5950-00-329-5719 |
Item Name : Transformer Power | CAGE Code : 13483 | FSC : 5950 Coils and Transformers |
Thank you for your vested interest in procuring the Transformer Power part types you require from The Distribution Pro! We currently have the Precision Electronics Corp item you require available and listed alongside the part number 4512 and the NSN 5950-00-329-5719. To begin the procurement process for part 4512 or any item, submit a Request for Quote (RFQ) form with all details relevant to your purchase. Our team of market experts use data such as target prices, shipping deadlines, and desired quantities to formulate customized quotations for your comparisons, all within 15 minutes or less.
With cost savings and rapid lead times, our inventory of manufacturer Precision Electronics Corp items like NSN 5950-00-329-5719 is organized to promote a procurement process that follows the motto: “as soon as possible, as simple as possible.” You can find Part 4512 listed next to the CAGE Code 13483 under FSC 5950 Coils and Transformers or you can search for specific details to find any other product you have in mind. As quality is the cornerstone of our operations, all NSN parts are sourced reliably from trusted manufacturers and shipped to you alongside all applicable trace documentation. Furthermore, we are an AS9120B, ISO 9001:2015, and FAA AC 00-56B accredited enterprise with a strict No China Sourcing policy, ensuring the premium quality of our inventory. When you are ready to begin procuring any item, submit an RFQ or contact us via phone or email for one-on-one assistance.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-00-329-5719 Item Description: Transformer Power | 5950 | 003295719 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
4512 | 6 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHEDNOT ESTABLISHED |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 5.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP5.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 3.125 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP3.125 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ACZB | FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT400.0 HERTZ NOMINAL SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | THREE PHASE TO SIX PHASE SINGLE COMPONENTTHREE PHASE TO SIX PHASE SINGLE COMPONENT |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENTINTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENT |
ADAQ | BODY LENGTH | 5.810 INCHES NOMINAL5.810 INCHES NOMINAL |
ADAT | BODY WIDTH | 4.190 INCHES NOMINAL4.190 INCHES NOMINAL |
ADAU | BODY HEIGHT | 3.060 INCHES MAXIMUM3.060 INCHES MAXIMUM |
AKNA | INCLOSURE TYPE | HERMETICALLY SEALEDHERMETICALLY SEALED |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP4 SINGLE GROUP |
AXGY | MOUNTING METHOD | THREADED HOLE SINGLE GROUPTHREADED HOLE SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 1 PRIMARY SINGLE COMPONENT AND 4 SECONDARY SINGLE COMPONENT4 SECONDARY SINGLE COMPONENT |
CMLP | THREAD QUANTITY PER INCH | 20 SINGLE GROUP20 SINGLE GROUP |
CQJX | NOMINAL THREAD SIZE | 0.250 INCHES SINGLE GROUP0.250 INCHES SINGLE GROUP |
CRBZ | WINDING OPERATING CURRENT | 1.63 AMPERES AC MAXIMUM SINGLE COMPONENT 4TH SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 1.83 AMPERES AC MAXIMUM SINGLE COMPONENT 3RD SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 4.87 AMPERES AC MAXIMUM SINGLE COMPONENT 2ND SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 7.2 AMPERES AC MAXIMUM SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 11.80 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 11.80 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY196.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY25.60 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 25.60 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY8.36 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 8.36 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 8.36 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY30.20 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY11.80 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
THSD | THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |
TTQY | TERMINAL TYPE AND QUANTITY | 32 TURRET |
![]() |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.