Mfg Part Number: 315-18691-01 | Alternate P/N: 3151869101 | Manufacturer: Oeco Corp |
NSN : 5950-01-231-0728 | Item Name : Coil Electrical | CAGE Code : 95266 |
FSC : 5950 Coils and Transformers |
Thank you for your vested interest in procuring the Coil Electrical part types you require from The Distribution Pro! We currently have the Oeco Corp item you require available and listed alongside the part number 315-18691-01 and the NSN 5950-01-231-0728. To begin the procurement process for part 315-18691-01 or any item, submit a Request for Quote (RFQ) form with all details relevant to your purchase. Our team of market experts use data such as target prices, shipping deadlines, and desired quantities to formulate customized quotations for your comparisons, all within 15 minutes or less.
With cost savings and rapid lead times, our inventory of manufacturer Oeco Corp items like NSN 5950-01-231-0728 is organized to promote a procurement process that follows the motto: “as soon as possible, as simple as possible.” You can find Part 315-18691-01 listed next to the CAGE Code 95266 under FSC 5950 Coils and Transformers or you can search for specific details to find any other product you have in mind. As quality is the cornerstone of our operations, all NSN parts are sourced reliably from trusted manufacturers and shipped to you alongside all applicable trace documentation. Furthermore, we are an AS9120B, ISO 9001:2015, and FAA AC 00-56B accredited enterprise with a strict No China Sourcing policy, ensuring the premium quality of our inventory. When you are ready to begin procuring any item, submit an RFQ or contact us via phone or email for one-on-one assistance.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-01-231-0728 Item Description: Coil Electrical | 5950 | 012310728 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | 0 | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
315-18691-01 | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABHP | OVERALL LENGTH | 1.800 INCHES NOMINAL |
ABHY | TURN QUANTITY | 108 SINGLE COMPONENT 5TH WINDING |
ABHY | TURN QUANTITY | 188 SINGLE COMPONENT 1ST WINDING |
ABHY | TURN QUANTITY | 240 SINGLE COMPONENT 2ND WINDING |
ABHY | TURN QUANTITY | 48 SINGLE COMPONENT 6TH WINDING |
ABHY | TURN QUANTITY | 64 SINGLE COMPONENT 4TH WINDING |
ABHY | TURN QUANTITY | 68 SINGLE COMPONENT 3RD WINDING |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.400 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.400 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKW | OVERALL HEIGHT | 1.231 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 1.800 INCHES NOMINAL |
ACYV | INDUCTANCE RATING | 1.047 MILLIHENRIES NOMINAL SINGLE COMPONENT 3RD WINDING |
ACZB | FREQUENCY RATING | 80.0 KILOHERTZ NOMINAL SINGLE COMPONENT |
AKDX | WINDING QUANTITY | 8 SINGLE COMPONENT |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
AXGY | MOUNTING METHOD | UNTHREADED STUD SINGLE GROUP |
BKPL | RATING METHOD | ELECTRICAL AND WINDING TURNS SINGLE COMPONENT ALL WINDING |
CQPZ | WINDING CONDUCTOR SIZE | 0.00631 INCHES AMERICAN WIRE GAGE SINGLE COMPONENT 1ST WINDING |
CQPZ | WINDING CONDUCTOR SIZE | 0.00795 INCHES AMERICAN WIRE GAGE SINGLE COMPONENT 2ND WINDING |
CQPZ | WINDING CONDUCTOR SIZE | 0.01003 INCHES AMERICAN WIRE GAGE SINGLE COMPONENT 3RD WINDING |
CQPZ | WINDING CONDUCTOR SIZE | 0.01003 INCHES AMERICAN WIRE GAGE SINGLE COMPONENT 4TH WINDING |
CQPZ | WINDING CONDUCTOR SIZE | 0.01594 INCHES AMERICAN WIRE GAGE SINGLE COMPONENT 5TH WINDING |
CQPZ | WINDING CONDUCTOR SIZE | 0.02010 INCHES AMERICAN WIRE GAGE SINGLE COMPONENT 6TH WINDING |
CRBZ | WINDING OPERATING CURRENT | 0.03 AMPERES DC MAXIMUM SINGLE COMPONENT 4TH WINDING |
CRBZ | WINDING OPERATING CURRENT | 0.21 AMPERES DC MAXIMUM SINGLE COMPONENT 6TH WINDING |
CRBZ | WINDING OPERATING CURRENT | 0.24 AMPERES DC MAXIMUM SINGLE COMPONENT 5TH WINDING |
CRBZ | WINDING OPERATING CURRENT | 0.36 AMPERES DC MAXIMUM SINGLE COMPONENT 2ND WINDING |
CRBZ | WINDING OPERATING CURRENT | 1.0 AMPERES DC MAXIMUM SINGLE COMPONENT 1ST WINDING |
CRBZ | WINDING OPERATING CURRENT | 1.25 AMPERES DC MAXIMUM SINGLE COMPONENT 3RD WINDING |
CRGS | DC RESISTANCE RATING IN OHMS | 0.200 SINGLE COMPONENT 1ST WINDING |
CRGS | DC RESISTANCE RATING IN OHMS | 0.550 SINGLE COMPONENT 3RD WINDING |
CRGS | DC RESISTANCE RATING IN OHMS | 0.700 SINGLE COMPONENT 5TH WINDING |
CRGS | DC RESISTANCE RATING IN OHMS | 1.000 SINGLE COMPONENT 6TH WINDING |
CRGS | DC RESISTANCE RATING IN OHMS | 1.030 SINGLE COMPONENT 2ND WINDING |
CRGS | DC RESISTANCE RATING IN OHMS | 6.700 SINGLE COMPONENT 4TH WINDING |
FEAT | SPECIAL FEATURES | 7TH WINDING 131 TURNS,24 AWG WIRE,1.6 ADC,0.71 OHMS;8TH WINDING 136 TURNS,24 AWG WIRE,0.17 ADC,4.9 OHMS |
TTQY | TERMINAL TYPE AND QUANTITY | 16 PIN |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.
Request for Quote