Mfg Part Number: 222-10NL-2221502 | Alternate P/N: 22210NL2221502 | Manufacturer: American Standard Inc |
NSN : 5930-00-058-3750 | Item Name : Switch Thermostatic | CAGE Code : 96452 |
FSC : 5930 Switches |
Thank you for your vested interest in procuring the Switch Thermostatic part types you require from The Distribution Pro! We currently have the American Standard Inc item you require available and listed alongside the part number 222-10NL-2221502 and the NSN 5930-00-058-3750. To begin the procurement process for part 222-10NL-2221502 or any item, submit a Request for Quote (RFQ) form with all details relevant to your purchase. Our team of market experts use data such as target prices, shipping deadlines, and desired quantities to formulate customized quotations for your comparisons, all within 15 minutes or less.
With cost savings and rapid lead times, our inventory of manufacturer American Standard Inc items like NSN 5930-00-058-3750 is organized to promote a procurement process that follows the motto: “as soon as possible, as simple as possible.” You can find Part 222-10NL-2221502 listed next to the CAGE Code 96452 under FSC 5930 Switches or you can search for specific details to find any other product you have in mind. As quality is the cornerstone of our operations, all NSN parts are sourced reliably from trusted manufacturers and shipped to you alongside all applicable trace documentation. Furthermore, we are an AS9120B, ISO 9001:2015, and FAA AC 00-56B accredited enterprise with a strict No China Sourcing policy, ensuring the premium quality of our inventory. When you are ready to begin procuring any item, submit an RFQ or contact us via phone or email for one-on-one assistance.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5930-00-058-3750 Item Description: Switch Thermostatic | 5930 | 000583750 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | S | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
222-10nl-2221502 | 2 | 1 | C | A |
MRC | Criteria | Characteristic |
---|---|---|
ABFE | III HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | DUSTPROOF AND VIBRATION RESISTANT AND WATERTIGHT |
ABHP | III OVERALL LENGTH | 5.188 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 5.687 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 2.812 INCHES NOMINAL |
ADAU | BODY HEIGHT | 2.750 INCHES NOMINAL |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.281 INCHES NOMINAL |
AEVT | CAPILLARY TUBE LENGTH | 120.0 INCHES NOMINAL |
AEVU | BULB LENGTH | 3.625 INCHES NOMINAL |
AEVV | BULB DIAMETER | 0.688 INCHES NOMINAL |
AFDS | LONGEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS | 2.406 INCHES NOMINAL |
AFDT | SHORTEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS | 0.656 INCHES NOMINAL |
AFDV | LONGEST VERTICAL DISTANCE BETWEEN MOUNTING CENTERS | 3.281 INCHES NOMINAL |
AKBY | TEMP SENSING ELEMENT TYPE | CAPILLARY TUBE-BULB |
AWTN | OPERATING TEMP RATING | 195.0 DEG FAHRENHEIT MAXIMUM |
AXGY | MOUNTING METHOD | BRACKET AND UNTHREADED HOLE |
CBBL | FEATURES PROVIDED | ELECTRICAL ACCESS PORT |
CQGB | CONTACT ACTION STIMULUS | INCREASE |
CQYJ | MOUNTING FACILITY PATTERN | ISOSCELES TRIANGLE |
CRLD | NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION |
CSCF | TERMINAL TYPE | SCREW |
CTHF | CONTACT LOAD CURRENT RATING | 16.0 AMPERES INDUCTIVE LOAD FIRST VOLTAGE |
CTHF | CONTACT LOAD CURRENT RATING | 2.0 AMPERES INDUCTIVE LOAD EIGHTH VOLTAGE |
CTHF | CONTACT LOAD CURRENT RATING | 2.5 AMPERES INDUCTIVE LOAD SEVENTH VOLTAGE |
CTHF | CONTACT LOAD CURRENT RATING | 3.2 AMPERES INDUCTIVE LOAD FOURTH VOLTAGE |
CTHF | CONTACT LOAD CURRENT RATING | 4.0 AMPERES INDUCTIVE LOAD THIRD VOLTAGE |
CTHF | CONTACT LOAD CURRENT RATING | 4.8 AMPERES INDUCTIVE LOAD SIXTH VOLTAGE |
CTHF | CONTACT LOAD CURRENT RATING | 8.0 AMPERES INDUCTIVE LOAD SECOND VOLTAGE |
CTHF | CONTACT LOAD CURRENT RATING | 9.6 AMPERES INDUCTIVE LOAD FIFTH VOLTAGE |
CTYC | CONTACT ADJUSTABILITY | ACTUATION POINT ADJUSTABLE |
CTYM | CONTACT ADJUSTMENT RANGE | +90.00/+165.00 ACTUATION POINT DEGREES FAHRENHEIT |
CTYS | CONTACT ADJUSTMENT TYPE | EXTERNAL ACTUATION POINT SCREW |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 115.0 AC AT SEA LEVEL FIRST VOLTAGE |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 115.0 DC AT SEA LEVEL FIFTH VOLTAGE |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 230.0 AC AT SEA LEVEL SECOND VOLTAGE |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 230.0 DC AT SEA LEVEL SIXTH VOLTAGE |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 440.0 AC AT SEA LEVEL THIRD VOLTAGE |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 440.0 DC AT SEA LEVEL SEVENTH VOLTAGE |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 550.0 AC AT SEA LEVEL FOURTH VOLTAGE |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 550.0 DC AT SEA LEVEL EIGHTH VOLTAGE |
MEDA | MEDIA FOR WHICH DESIGNED | GAS OR LIQUID |
PMLC | III PRECIOUS MATERIAL AND LOCATION | CONTACTS SILVER |
PRMT | PRECIOUS MATERIAL | SILVER |
STYL | III STYLE DESIGNATOR | RECTANGULAR |